Blood Cell Counter  
       
  Hematology  
       
    3 Part Differential  
       
      MS4  
           
      MS4e  
           
      MS9  
           
      MS93  
           
      MS93S  
           
    5 Part Differential  
           
      MS45  
           
      MS95  
           
  Electrolyte Analyzer  
           
    Biolyte 2000  
           
  Urine Analyzer  
       
    NUANCER  
       

 
 

Products -> Hematology -> 3 Part Differential -> MS4

SMALL PRICE ... SMALL SIZE
BUT OH SO... SMART!

  Features  
     
 
  • Totally automatic
  • 18 parameters (L-M-G) and 3 histograms
    (visualised and printed)
  • Quadridimensional numeric cellular analysis
  • 3 pre-programmed digital data banks (Man, Woman, New Born) and 2 undefined banks
  • A mere 16 µl allow the operator to obtain a complete blood check-up
  • Bar code(1) and/or alphanumeric identification
  • Operations carried out on an open and/or sealed tube (Optional)
  • Database and quality control software
  • Neither handling nor service needed
  • Extremely compact (width 21cm, height 33 cm, depth 24 cm, 12 Kg)
  • Very economical
  • 5 years warranty(Under usual warranty conditions)

 
 
     
  Simplicity  
     
 
  • 5 numeric data banks offering rapid access and selection (Man, Woman, New Born, 2 Undefined)
  • Input of the identification with a PC alphanumeric keyboard(1) and/or bar-code (Optional)
  • Graphic screen
  • Operations carried out with an open and/or sealed tube(Optional)
  • Complete cleaning after each cycle
  • Totally automatic daily cleaning

 
     
  Power  
     
 

NO HANDLING, ENTIRELY AUTOMATIC
One manipulation, one test.... Forget about all the rest !

ONE DROP OF BLOOD IS ENOUGH
A mere 16 µl allow the operator to obtain complete and trustworthy results.

18 PARAMETERS & L-M-G
Parameters measured and calculated in a few seconds, with 3 cellular distribution histograms.

QUALITY CONTROL
3-level control blood management program.
Edition of complete quality-control reports.

DATABASE
100 files on-line with histograms.
Post-editions and studies.
Edition and/or data transfer on computer media.

RELIABLE ACCURATE ANALYSIS
Quadridimensional numeric cellular analysis.
5 counts per canal at fixed time periods.
Double electronic detection of possible blockings.

 
  Innovation  
     
 

NUMERIC CONCEPT
Flexibility and sophisticated operative capabilities.
Reliability and stability of results throughout time.
Simplicity and reduced size of the electronic equipment.

MS-CARD®
Smart card managing the generic reagents.
Enables the laboratory to work with its usual reagents.

ELECTRONICALLY-CONTROLLED VALVE
Electronically balance-controlled valve (no clipping of tubes).
Avoids the maintenance problems of the diluter.
Clot filters installed to avoid the blockages.